BJX-G不銹鋼防爆接線箱
執行標準 APPLICABLE STANDARD
GB3836.1-2000爆 炸性氣體環境用電氣設備第1部分:通用要求
GB3836.3-2000 爆 炸性氣體環境用電氣設備第2部分:隔爆型“d”
GB3836.1-2000 Electrical apparatus for explosive atmosphereselectrical apparatus section 1:general requires
GB3836.3-2000 Electrical apprartus for explosive atmospheres flameproof electrical apparatus section 2:Flame-proof"d"
適用范圍 APPLICATION SCOPE
1區、2區危險場所;
爆 炸性氣體混合物;IIA、IIB、IIC。
溫度組別T1-T6。
進出線規格方向、數量端子數量及端子的額定電流、防護等級、布線和填料函型式及安裝型等均可滿足顧客的需要。
Hazardois zone:zone 1,zone 2
Explosive gas mixture:IIA,IIB,IIC
Temperature level:T1-T6
The direction and quantity of inlet and outlet,quantity,rated current,protection,wiring of terminals and gland type can beaeeanged according to customers request.
特點CHARACTERISTICS
不銹鋼外殼或優質鋼板,表面靜電噴涂處理;
內可裝大容量接線端子
鋼管或電纜布線均可,電纜布線須配電纜夾緊密封填料函。
Stainless steel housing with static-electrically sprayed powder surtace
Terminals of large capacity will be arranged inside of the juntion box
Cable transit arranged with conduit or armored gland
主要技術參數 MAIN TECHICAL PARAMETER
額定電壓:AC660V以下
額定電流:125A以下
防護等級:IP66 防爆標志:ExdIIBT4
Rated voltage:AC500V below
Rated Current:100A below
Protection Class:IP66 Exp-proof Mark:ExdIIBT4
訂貨須知 ORDER NPTICE
額定電壓、電流、頻率
元件數量、名稱或完整的型號
名牌材質、式樣及字樣要求
所用電纜的最大外徑
箱體材質及顏色
安裝方式
入級要求(執行船檢的船級社)
非標準產品需提供詳細技術資料
Rated voltage,current and frequency
Quantity of components,name or model
Request for nameplate material,and pattern
Maxinum outside diameter of all the cables
Housing material and color
Mount type
Classification Societies Requirement(Cl